SYS 680 ci

POWERFUL PEAK PRODUCTIVITY & EFFICIENCY

The SYS 680 ci is expertly crafted for high-volume laboratories, blending cutting-edge automation with unmatched efficiency and reliability for seamless performance.

  1. Analytical Methodologies: photometric and potentiometric methodologies, ensure accurate and reliable results for a broad spectrum of tests.
  2. Reagent Management: advanced reagent management system with refrigerated compartments to maintain reagent stability.
  3. Throughput and Capacity: high throughput of up to 600 tests per hour.
  4. Comprehensive Test Menu: routine chemistry panels, liver function tests, renal function tests, lipid profiles, and more.
  5. Flexibility in Sample Management: Continuous Sample Loading, STAT Sample Priority, Barcode scanning.

Technical Specifications

System Function:

  • Throughput: 600 photometric tests per hour, up to 800 tests per hour with ISE
  • Measuring principles: Absorbance Photometry, Turbidimetry
  • On-board tests: up to 77 photometric tests + 3 ISEs+ 3 serum indices
  • Methodology: End-point, Fixed-time, Kinetic, ISE

Sample Handling:

  • SDM: 120 samples by 12 racks, sample continuous loading, STAT in priority
  • Sample volume: 1.5~45µL, step at 0.1µL
  • HbA1c sample: Whole blood for HbA1c test
  • Sample probe: Liquid level detection, clot detection and collision protection

Reagent Handling:

  • Reagent tray: 80 positions with cooling system (2~8°C)
  • Reagent volume: 10~200µL, step at 0.5µL
  • Reagent probe: Liquid level detection, bubble detection, and collision protection

Built-in Bar Code Reader:

  • Sample and reagent bar code readers support Codabar, ITF (Interleaved Two of five), Code 128, Code 39, UPC/EAN and Code 93;
  • Capable to connect with LIS in the bi-directional mode

Reaction System:

  • Reaction volume: 70~300µL
  • Reaction temperature: 37°C with 0.1°C fluctuation
  • Reaction cuvettes: 124 reusable cuvettes with 8-step auto wash

Optical System:

  • Light source: Tungsten-halogen lamp
  • Photometer: Grating photometer
  • Wavelength: 16 wavelengths (340nm, 380nm, 412nm, 450nm, 480nm, 505nm, 546nm, 570nm, 605nm, 630nm, 660nm, 700nm, 740nm, 770nm, 800nm, 850) nm
  • Absorbance range: 0~3.5Abs(10mm conversion)
  • Control and Calibration: Calibration mode: Linear(one-point, two-point and multi-point), Logit-Log 4P, Logit-Log 5P, Spline, Exponential, Polynomial, Parabola
  • Control rules: Westgard multi-rule, Twin plot

Operation Unit:

  • Operation system: Touch screen(optional), Windows 10(64bit)
  • Interface: RS-232, Network Port, USB/ parallel port

Working Conditions:

  • Power Supply: 200~240V, 50/60Hz, 1700VA or 110/115V, 60Hz, 1700VA
  • Temperature: 15~30°C
  • Humidity: 35~85%
  • Dimension: 1380mm(length)*860mm(width)*1200mm(high)
  • Weight: 350kg

Water Consumption:

Average Water Consumption: ≤25 L/h

For more details, please get in touch. Click Here

DiaSys 680 ci: POWERFUL PEAK PRODUCTIVITY & EFFICIENCY